CURRENT INJECTION SETS
Features:
- Built in µp based time interval meter measuring from 1 millisec to 9999 secs.
- Panel with easy & clear legends to read.
- Continuously variable outputs.
- Digital ammeter & voltmeter.
- Auto cut-off & output isolated.
- Self sensing of contacts i.e. NO or NC.
- Potential free start - stop signals.
- Fully portable , table top models with metal cover
Primary current injection sets
|
Model |
Current
Output AC |
Metering |
|
AEP -
1 |
1000 A / 2
V |
500 A /
4V |
250A /
8V |
|
a) 3 1/2
Digit, Digital ammeter OR b) Analog ammeter with multiplying
factor |
|
AEP -
2 |
1000 A / 5
V |
500 A /
10V |
250A /
20V |
|
|
AEP -
3 |
2000 A / 2
V |
1000 A /
4V |
500A /
8V |
250 A /16
V |
|
AEP -
4 |
2000 A /
4V |
1000 A /
8V |
500A /
16V |
250 A /32
V |
|
AEP -
5 |
3000 A / 2
V |
1500 A /
4V |
750A /
8V |
|
|
AEP -
6 |
4000 A / 2
V |
2000 A /
4V |
1000A /
8V |
|
|
AEP -
7 |
5000 A / 2
V |
2500 A /
4V |
1250A /
8V |
|
| Supply voltage |
230V AC +/- 10%,50 Hz. |
| Indications |
Main ON, Output ON, Output OFF. |
| Operation |
Contactor controlled push buttons for output ON/OFF. |
| Duty cycled |
30 Min ON /15 min. OFF. |
| Protection |
a) Fuse / MCB . b) Over current protection. |
| Termination |
The outputs are brought out on the suitable bus bars. |
Secondary current injection sets / Relay test sets
|
Models |
Current
output AC, Variables |
Optional
voltage Output |
|
AC |
DC |
|
AE
-1 |
100A / 3
V |
75A / 4
V |
50A /
6V |
25A /
12V |
5A /
60V |
2A /
150V |
250 V /
2A |
250 V /
1.5A |
|
AE-2 |
200A / 4
V |
100A / 8
V |
50A /
16V |
25A /
32V |
10A /
80V |
5A /
160V |
250 V /
4A |
250 V /
1.5A |
|
AE-3 |
300A / 4
V |
200A / 6
V |
150A /
8V |
100A /
12V |
50A /
24V |
4A /
250V |
250 V /
4A |
250 V /
1.5A |
|
RTS
25 |
25A / 10
V |
5A / 50
V |
- |
- |
|
|
250 V /
1A |
250 V /
1A |
| Supply voltage |
230V AC +/- 10%,50 Hz. |
| Metering |
a) 3 1/2 Digit digital Voltmeter
b) 3 1/2 Digital percentage Ammeter
c) 4 Digit µp based time interval meter 9.999 / 99.99 / 999.9 / 9999 secs. selectable. |
| Timer Control Circuit |
The timer automatically starts when the output is initiated and automatically stops when the device under test operates. |
| Test Conditions |
a) Current activated device without auxiliary contacts.
b) NO contacts.
c) NC contacts. |
| Auto cut-off |
Cuts off output on operation of item under test. |
| Operation |
Contactor controlled push buttons for output ON/OFF. |
| Duty cylced |
120Min ON / 30 min. OFF. |
| Indications |
Main ON, Output ON, Output OFF. |
| Protection |
a) Fuse / MCB . b) Over current protection. |
|